Home » Products » ICU Equipment » Multipara Patient Monitors

Multipara Patient Monitors

Multipara Patient Monitors
Send Inquiry
Product Code : SPO2+Pulse rate + NIBP Optional ECG, TEMP
Price And Quantity
  • Minimum Order Quantity
  • 1 Piece
  • Price
  • 220-890 USD ($)
  • Price Range
  • 220.00 - 890.00 USD ($)
Product Specifications
  • Equipment Type
  • MEDICAL
  • Material
  • Plastic
  • Condition
  • New
  • Technology
  • USA , CHINA
  • Portable
  • YES
  • Wall Mounted
  • Yes
  • Real-Time Operation
  • Yes
  • Operating Type
  • Automatic
  • Use
  • HOME AND ICU,NICU
  • Power Source
  • Electric
  • Power Consumption
  • 50 Watt (W)
  • Voltage
  • 12-240 Volt (v)
  • Weight
  • 4 Kilograms (kg)
  • Color
  • WHITE,BLACK,BLUE
Product Description

                  


TECHNICAL SPECIFICATIONS
 

Quality Standards and Classification
CE, ISO13485
Anti- Ectroshock degree: Class I Equipment (internal power supply)
TEMP/Spo2/NIBP

ECG/Resp,PULSE     

Application Range:
Adult/Pediatric/Neonatal/Medicine/Surgery/Operating Room/ICU/CCU

Display:
12.1 real color TFT screen

One alram indicator (yellow/red)
One working indicator(green)
One battery charge state indicator (green)
Three modes in accordance with the alarm state

Environment
Operating Environment:
Temperature: 0-40 C
Humidity <85%
Altitude 500-4600m
Transport and Storage environment:
Temperature 20-60 C
Humidity <93%
Altitude 500-13100m

Power Requirements:
AC: 100-240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 4000mA 11.1V lithium battery
   2h operating after full charge (one piece)
   5min operating after low battery alarm

Dimension and Weight:
Equipment:
305mm* 160mm* 287mm, 3.8Kg
Package
380mm* 350mm* 300mm, 6.1Kg

Date Storage:
Trend diagram/table 7x24h
NIBP review  400 events
Wave review 100min
Alarm review 100 alarm events
Support drug concentration titration analysis

ST Segment:
ST Segment Range: -2.0mV-+2.omV
Accuracy: 0.02mV

ECG:

5 Leads: RA,LA, LL, RL, V
Leads mode: I,II, II, aVR, aVL, aVF, V
Increase: x250, x500, x1000, x2000
Sensitivity: > 200 uV(Peak-to-peak value)
Input impedance: > 5(megohm)
Bandwidth: Surgery 1-20Hz
           Monitor 0.5-40Hz
           Diagnostic 0-05-130Hz
           CMRR: >100dB
Polarization Voltage: +300mV
Baseline Recovering Time: After defibrillation <3 seconds
Signal Range: 8mV (Peak-to-peak value)
Calibrating Signal: 1mV, Precision +5%

RESP:
Method: RA-LL impedance
Resp Impedance range: 0.3-3om
Base Impedance range: 200-4000om
Bandwidth: 0.1-2.4Hz
Resp rate: Adult 0-120BrPM
           Neonatal/pediatric 0-10BrPM
           Resolution:  10BrPM
           Precision: +2BrPM
Asphyxia Alarm 10-40 seconds

NIBP:
Method: Pulse Wave oscillometry
Work mode: Manual/Auto/STAT
Measure interval of auto mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480, minut(s)
Measuring Time of STAT mode: 5 minuts(s)
PR range: 40-240bpm
Measure & Alarm range: Adult
              SYS   40-27mmHg
              DIA   10-215mmHg
              MEAN  20-235mmHg
                  Pediatric
              SYS   40-200mmHg
              DIA   10-150mmHg
              MEAN  20-165mmHg
                  Neonatal
              SYS   40-135mmHg
              DIA   10-100mmHg
              MEAN  20-110mmHg
Static Pressure range 
0-300mmHg
Precision:+3mmHg
Pressure Precision:
    Max average error: +5mmHg
    Max standard deviation: +8mmHg
   
Over voltage protection
   Adult 300mmHg
   Pediatric 240mmHg
   Neonatal  150mmHg
  
SpO2:
Range 0-100%
Resolution: 1%
Precision: 70%-100% +2GIGIT
0%-69%: +no definitiongiven

Pulse Rate
Range:  20-300bpm
Resolution: 1bpm
Precision: +3bpm


TEMP:
Channel    2
Measure & Alarm Range: 0-50C
Resolution:   0.1C
Precision (No sensor):  +0.1C

Standard accessories
* NIBP cuff & Tube
*ECG cable & electrodes
*SpO2 sensor
*TEMP probe
*Lithium-ion battery
*Power cable
* Operator's manual

Optional accessories:
*CO2 module
*IBP module
*Touch Screen
*Trolley bracket
*Hanging brancket
*Monitor recorder
IBP:
Label ART, PA, CVP, RAP, LAP, ICP, P1,P2
Measuring and alarm range
ART   0-300mmHg
PA    -6-120mmHg
CVP/RAP/LAP/ICP -10-40mmHg
P1/P2   -10-300mmHg
Press Sensor
Sensitivity 5uV/VmmHg
Impedance 300-3000Om
Resolution: 1mmHg
Accuracy: +2% or +1mmHg, wich great
Actualization interval: about 1 sec
CO2:
Side/Main stream
Warm-ip time:
when the ambient temperature is 25 C, the carbon dioxide curve (capnogram) can be displayed within 20/15 second, and all the specifications can be fulfilled within 2 minuts
Measurement range:
0-150mmHg, 0-19.7%, 0-20kPa (760mmHg)
atmospheric pressure provided by the host
Resolution 0.1mmHg: 0.69mmHg
0.25mmHg: 70-150mmHg
Precision 0-40mmHg: +2mmHg
41-70mmHg: +5% (reading)
71-100mmHg: +8% (reading)
101-150mmHg: +10% (reading)
Respiratory rate range  0-150BPM
REspiratory rate Accuracy  +1BPM           
           

Trade Information
  • FOB Port
  • NEW DELHI
  • Payment Terms
  • Telegraphic Transfer (T/T), Cheque
  • Supply Ability
  • 2000 Piece Per Month
  • Delivery Time
  • 15 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • BOX
  • Main Export Market(s)
  • Africa, Middle East, Western Europe, Eastern Europe, South America, North America, Central America, Australia, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • CE EUROPE , ISO